  high performance rfi power line filters for medical equipment the ht series power line filters provide superior common- mode and premium differential-mode attenuation to rfi noise on the frequency range from 10khz to 30mhz, for iec 60601 and ul2601 patient-connected equipment, as well as all other electronic equipment that cannot tolerate leakage current. they are a size- and cost-effective solution to the problem of meeting both medical leakage current limits and conducted emissions limits in equipment with high noise sources (such as switching power supplies). ht series filters can meet the following conducted emissions standards: ? european normalized standards based on en55022, level a (in many cases, level b also). ? fcc part 15, computing devices, class b. ? fcc part 18, ism equipment, industrial and consumer. note: when using the models with an iec connector, remember that the leakage current of the companion line cord, ga400, is more significant than that of the filter - which may disqualify this line cord from use in patient care applications. for more information on ul2601, see appendix c. specifications maximum leakage current,each line-to-ground @ 120 vac 60 hz: 2 a @ 250 vac 50 hz: 5 a hipot rating (one minute): line-to-ground 1500 vac line-to-line 1450 vdc operating frequency: 50/60 hz rated voltage (max.): 250 vac minimum insertion loss in db: line-to-ground in 50 ohm circuit current frequency?hz rating .01 .02 .05 .08 .15 .5 1 2 5 10 20 30 3a 22 32 36 - 49 46 40 30 22 12 12 12 6a 16 23 32 41 46 41 33 26 15 9 6 2 10a 9 15 24 30 36 42 34 22 11 12 8 8 15a 4 9 18 22 27 41 34 22 12 12 5 2 line-to-line in 50 ohm circuit current frequency?hz rating .01 .02 .05 .08 .15 .5 1 2 5 10 20 30 3a 3 1 30 - 61 70 65 65 48 40 32 32 6a 4 1 14 45 51 70 70 65 55 47 37 37 10a 7 8 17 32 52 70 70 70 65 55 40 35 15a 12 16 15 10 51 70 70 70 70 70 65 55 70 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. ht series ht series corcom product guide electrical schematics 3 & 6 amp 10 amp 15 amp ht1 h t7 ht6 h t3 ul recognized csa certified vde approved resistor location for reference only. line load line load line load
high performance rfi power line filters for medical equipment (continued) case styles recommended panel cutout case dimensions a b c d e .015 part no. (max) (max) (max) (max) .38 3eht1, 6eht1 3.56 2.15 1.81 2.938 3.38 90.4 54.6 46.0 74.63 85.9 3EHT3, 6eht3 2.55 2.15 1.81 2.938 3.38 64.8 54.6 46.0 74.63 85.9 3eht7, 3eht7m, 3.52 2.25 1.78 1.575 0.63 6eht7, 6eht7m 89.4 57.2 45.2 40.01 16.0 10eht1 4.69 2.27 1.8 4.063 4.47 119.1 57.7 45.7 103.2 113.5 10eht3 3.69 2.27 1.8 4.063 4.47 93.7 57.7 45.7 103.2 113.5 15eht1 5.45 3.12 2.18 3.5 3.96 138.4 79.2 55.4 88.9 100.6 15eht6 5.95 3.12 2.18 3.5 3.96 151.1 79.2 55.4 88.9 100.6 71 catalog 1654001 dimensions are in inches and dimensions are shown for usa cust. svc.: 1-800-468-2023 www.corcom.com revised 05-07 millimeters unless otherwise reference purposes only. corcom prods: 1-847-680-7400 www.tycoelectronics.com specified. values in italics specifications subject germany: 49-89-6089-0 are metric equivalents. to change. r f i p o w e r l i n e f i l t e r s ht series corcom product guide ht1 (3, 6 and 10 amp) ht3 ht1 (15 amp) ht6 typical dimensions: t erminals: .250 [ 6 .35 ] (5) holes: .07 [ 1 .8 ] dia.(4) slot: .07 x .16 [ 1 .8 x 4.1 ] m ounting holes: .188 [ 4 .78 ] dia. (2) typical dimensions: wire leads: 4.0 [ 101.6 ] min. mounting holes: .188 [ 4.78 ] dia. (2) typical dimensions: terminals: no. 8-32 (5) mounting holes: .203 x .156 [ 5.16 x 3.96 ] dia. (4) torque: 18? in.lb ? ? ?02 [ ?5 ] part numbers 6eht1 10eht1 6eht3 10eht3 6eht7 15eht1 6eht7m 15eht6 line cord no. ga400 7 1/2 foot, 3-conductor line cord to mate with t7 models ht7 & ht7m (with metric insert) panel cutout (back mount) tolerance .005 [ 0.13 ] tapped insert no. 6-32 x 1/4 (2) - t7 no. m-3 x 5 (2) - t7m typical dimensions: terminals: .250 [ 6.35 ] (5) holes: .07 [ 1.8 ] dia.(4) slot: .07 x .16 [ 1.8 x 4.1 ] mounting holes: .203 x .156 [ 5.16 x 3.96 ] dia. (4) b c d a e brown green/yellow blue blue brown a d e c b edb a 2.00.01 50.80.25 c edb c 2.00.01 50.80 .25 a b d e c a 1 .575 40.01 0.910 2 3.1 0 .157 3.98 dia. 0 .235 5.96 r 1.295 32.89 b d e c a 1.575 4 0.01 0.910 23.1 0.157 3.98 d ia. 0 .235 5.96 r 1.295 3 2.89


▲Up To Search▲   

 
Price & Availability of 3EHT3

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X